Transmission lines need to be inspected according to regulation periodically. A minimum clearance for vegetation is essential to prevent flashovers. A Qube240 system was used for UAV LiDAR mapping on thin 20 kV lines, inspecting and mapping the corridor comprising lines, poles, and vegetation.
UAV Type | Trinity F90+ |
Flight Altitude | 90 m AGL |
Flight Time | 17 min |
Mission size | 14.5 Ha / 0.145 sq km |
Temperature | 30 degrees Celsius |
Payload | Qube240 LiDAR System |
Point Density | 104 pts/sqm |
Overlap | Side 50% |